Title: Use of a disposable sheath system for flexible sigmoidoscopy in decentralized colorectal cancer screening
Authors: Bretthauer, Michael
Hoff, Geir
Thiis-Evensen, Espen
Grotmol, Tom
Larsen, Inger K.
Kjellevold, Øystein
Skovlund, Eva
Issue Date: 2002
Publishers version: http://dx.doi.org/10.1055/s-2002-34273
Popularized abstract: Dette er en randomisert undersøkelse for sammenligning av standard skop, som må gjennomgå tidkrevende rengjøring og desinfeksjon før hver undersøkelse, versus et ”engangsskop” hvor dette ikke er nødvendig. Ved bruk av engangsskopet var det noe dårligere evne til å påvise polyper <5mm i diameter. Engangsskopene var nyttige ved desentralisert screening på satelittsentre hvor installering av skopvaskemaskiner ikke er praktisk gjennomførbart. Konklusjonen er at engangsskop bør kunne videreutvikles og være konkurransedyktige. Studien har overføringsverdi til klinisk virksomhet.
Abstract: Background and Study Aims: To prevent transmission of infectious agents and to reduce instrument reprocessing time, the use of disposable sheath systems instead of conventionally reprocessed endoscopes has been promoted for flexible sigmoidoscopy. This trial primarily investigated the feasibility of a disposable sheath system for flexible sigmoidoscopy in decentralized colorectal cancer screening.Patients and Methods: In an ongoing colorectal cancer screening trial, 226 consecutive participants were randomly allocated to have their flexible sigmoidoscopy performed with either a fiberoptic sigmoidoscope covered with a disposable sheath (“EndoSheath group”) or a conventional video colonoscope (“standard colonoscope group”). All examinations were performed at a temporary screening center. The patients' experience was documented using a questionnaire. The feasibility of running temporary screening units was evaluated.Results: Examinations beyond the 60-cm level were excluded. Thus, 113 patients (examined with the disposable instrument) and 87 (standard instrument) were eligible for analysis. When the sheathed system was used, all the devices needed could be satisfactorily transported. A screening center could be set up within a few hours. No differences were observed in patient discomfort. Fewer patients with polyps were observed in the EndoSheath group (48 [42 %]), compared with 55 (63 %) in the standard colonoscope group; P = 0.005). No significant differences were observed for polyps larger than 5 mm (14 [12 %] in the EndoSheath group, 13 [15 %] in the standard colonoscope group; P = 0.6).Conclusions: Using the disposable system, decentralized colorectal cancer screening was easily established. However, fewer polyps were found, possibly due to the fiberoptic nature of the instrument. Sheathed video instruments are desirable and may increase the diagnostic yield.
Keywords: Tykktarmskreft
Endoskoper
Engangsskoper
Publisher: Thieme
Document type: Journal article
URI: http://hdl.handle.net/2282/484
Appears in Collections:Onkologi

This item is protected by a usage licens. All items in TEORA are protected by copyright.

 

TEORA runs on DSpace 1.4
Telemark University College owns all rights for this page
Telemark University College, Library, Postboks 203, 3901 Porsgrunn
Telephone: 35952543, Email: teora@hit.no
Webmaster: Arild Skalmeraas
Technical webmaster: Rune Pettersen
Editor: Biblioteksjef Frode Bakken