Title: Effect of operating conditions and particle properties on performance of vertical air-lift
Authors: Chladek, Jana
Enstad, Gisle
Melaaen, Morten Christian
Issue Date: 2011
Abstract: The effect of the fluidization air flow rate and the transport air velocity on the solids mass flow rate and the pressure drop along the transport pipe was investigated in a vertical air-lift. The use of two different materials, glass (150 μm) and zirconium oxide (260 μm) particles (Geldart’s B class), enabled to estimate the effect of particle properties on the air-lift performance. Different levels of the solids mass flow rate were obtained by varying the fluidization air flow rate while keeping the transport air velocity constant. The solids loading ratio varied between 2 and 16 for both types of particles. The pressure drop was nonlinearly related to the solids mass flow rate at most of the transport air velocities tested. State diagrams presenting the relationship between the transport air velocity, the solids mass flow rate, and the pipeline pressure drop were constructed to characterize the flow pattern and to compare the behavior of the glass and zirconium oxide particles. Owing to the larger size and higher density, the zirconium oxide particles displayed higher pressure drop values than the glass beads and the minimum pressure drop shifted towards higher transport air velocities. The velocity at the transition between dilute and dense phase conveying was approximately in the range of 7 to 10 m/s for glass beads and 10 to 12 m/s for zirconium oxide, at the solids mass flow rates tested. The flow patterns could be also effectively characterized from the analysis of the pressure drop fluctuations at different transport air velocities.
Keywords: Pneumatic conveying
Vertical air-lift
Fluidization
Transport air velocity
Solid mass flow rate
pipeline pressure drop
Publisher: Elsevier
Document type: Journal article
URI: http://hdl.handle.net/2282/1174
DOI: http://dx.doi.org/10.1016/j.powtec.2010.10.013
Appears in Collections:Institutt for prosess-, energi- og miljøteknologi

This item is protected by a usage licens. All items in TEORA are protected by copyright.

 

TEORA runs on DSpace 1.4
Telemark University College owns all rights for this page
Telemark University College, Library, Postboks 203, 3901 Porsgrunn
Telephone: 35952543, Email: teora@hit.no
Webmaster: Arild Skalmeraas
Technical webmaster: Rune Pettersen
Editor: Biblioteksjef Frode Bakken